The DPT series is intended for use in commercial environments. It is designed with six unit selections (Pa, kPa, mbar, inchWC, mmWC, psi) and eight field selectable measurement ranges (unidirectional and bi-directional) to meet your job measurement requirements. The DPT-R8 series is comprised of the DPT250-R8 with ranges from 25 Pa to 250 Pa, the DPT2500- R8 with ranges from 100 Pa to 2500 Pa
SPECIFICATIONS:
Performance Accuracy
(from applied pressure):
±1,5 % + 1 Pa
(including: general accuracy, temperature drift, linearity, hysteresis, long term stability, and repetition error)
Thermal effects:
Temperature compensated across the full spectrum of capability.
Overpressure:
Proof pressure: 25 kPa
Burst pressure: 30 kPa
Zero point calibration:
Automatic auto zero or manual pushbutton Response time: 4.0 s or 0.8 s, selectable via jumper
Physical
Dimensions:
Case: 90.0 x 95.0 x 36.0 mm
Weight:
150 g Mounting: 2 each 4.3 mm screw holes, one slotted
Materials:
Case: ABS Lid: PC
Protection standard:
IP54 Display (Optional) 2-line display (12 characters/line)
Line 1: active measurement
Line 2: units
Electrical
Voltage:
Circuit: 3-wire
(V Out, 24 V, GND)
Input: 24 VAC or VDC, ±10 %
Output: 0–10V
Power consumption: <1.0w
Resistance minimum: 1 kΩ
Current:
Circuit:
3-wire (mA Out, 24 V, GND) Input: 24 VAC or VDC, ±10 %
Output:
4–20 mA, selectable via jumper Power consumption: <1.2w
Maximum load: 500 Ω
Technical Specifications:
Media compatibility:
Dry air or non-aggressive gases
Measuring units:
Pa, kPa, mbar, inchWC, mmWC, psi, selectable via jumper
Measuring
element: Piezoresistive
Environment:
Operating temperature: -10…50 °C
Storage temperature: -20…70 °C
Humidity: 0 to 95 % rH, non-condensing
Electrical
connections: 4-screw terminal block
Wire: 12–24 AWG (0.2–1.5 mm2 ) Cable entry: M16
Pressure fittings:
Male Ø 5,0 mm and 6,3 mm + High pressure − Low pressure
Conformance
Meets the requirements for CE marking:
EMC Directive 2004/108/EY RoHS Directive 2002/95/EY
Reviews